Airworthiness Directive

AD 2004-09-30 Amendment 39-13620

Federal Aviation Administration · 14 CFR part 39

FR document
04-10179
Amendment
39-13620
Published
2004-05-11
Models covered
1
Last live check
Not yet re-verified
AD

2004-09-30

FR doc 04-10179

AD 2004-09-30Published 2004-05-11Effective 2004-06-18

Requires you to replace the 200-amp electrical power current limiter in the landing gear with a 60- amp electrical power circuit breaker.

Full official abstract

The FAA adopts a new airworthiness directive (AD) for certain Raytheon Model 1900C airplanes. This AD requires you to replace the 200-amp electrical power current limiter in the landing gear with a 60- amp electrical power circuit breaker. This AD is the result of reports about the inability to automatically lower the landing gear and the inability to operate other related electrical systems. We are issuing this AD to prevent heat damage to the electrical wiring in and around the landing gear electrical systems components, which could result in the inability to operate critical control systems. This failure could lead to loss of control of the airplane.

Applies to 1 model in our index