Airworthiness Directive

AD 99-22-05 Amendment 39-11383

Federal Aviation Administration · 14 CFR part 39

FR document
99-27326
Amendment
39-11383
Published
1999-10-22
Models covered
1
Last live check
Not yet re-verified
AD

99-22-05

FR doc 99-27326

AD 99-22-05Published 1999-10-22Effective 1999-11-26

Requires repetitive inspections of the elevator trim control cables for signs of wear damage or broken wires; replacement of damaged or broken cables with certain new cables; and replacement of all 7 x 7 cables with 7 x 19 cables.

Full official abstract

This amendment adopts a new airworthiness directive (AD), applicable to all Short Brothers Model SD3-60 series airplanes, that requires repetitive inspections of the elevator trim control cables for signs of wear damage or broken wires; replacement of damaged or broken cables with certain new cables; and replacement of all 7 x 7 cables with 7 x 19 cables. This amendment is prompted by issuance of mandatory continuing airworthiness information by a foreign civil airworthiness authority. The actions specified by this AD are intended to prevent failure of the elevator trim cable due to fatigue cracking, which if not corrected, could result in reduced controllability of the airplane.