Airworthiness Directive

AD 95-12-12 60 FR 31063

Federal Aviation Administration · 14 CFR part 39

FR document
95-14050
Amendment
39-9262
Published
1995-06-13
Models covered
1
Last live check
2026-08-17
AD

95-12-12

FR doc 95-14050 · 60 FR 31063

AD 95-12-12Published 1995-06-13Effective 1995-06-28

Requires repetitive operational testing of the stall warning computers to ensure activation of the associated stick shakers, and replacement of non-operational stall warning computers with new or serviceable units.

1 correction to this AD FAA · 1995-08-11

Correction published 1995-08-11

Issued by
Federal Aviation Administration
Published
1995-08-11
Document
Federal Register 95-19655 · Final rule; correction
Corrects
the version published June 13, 1995 at 60 FR 31063

This document corrects a typographical error that appeared in airworthiness directive (AD) 95-12-12 that was published in the Federal Register on June 13, 1995 (60 FR 31063). The typographical error resulted in a reference to a part number that does not exist. This AD is applicable to certain de Havilland Models DHC-8-102, -103, and -106 series airplanes and requires repetitive operational testing of the stall warning computers.

A correction restates part of an AD that was published incorrectly. It is not an additional requirement and it does not change the AD number or its effective date.

Source: Federal Register document 95-19655, retrieved 2026-08-17

Full official abstract

This amendment adopts a new airworthiness directive (AD) that is applicable to certain de Havilland Model DHC-8-102, -103, and -106 series airplanes. This action requires repetitive operational testing of the stall warning computers to ensure activation of the associated stick shakers, and replacement of non-operational stall warning computers with new or serviceable units. This action also provides an optional terminating action for the repetitive operational tests. This amendment is prompted by a report that, during a routine test, the stick shakers of the stall warning system did not activate, due to contamination of the weight-on-wheels contacts in the stall warning computer. The actions specified in this AD are intended to ensure that such contamination is detected. Contamination of the stall warning computers could lead to incorrect logic detection of the weight-on- wheels signal, and subsequent loss of the stick shaker function.

Applies to 1 model in our index